stored pressure type

Thank you for considering Minimaxfire for your fire safety needs. We are dedicated to protecting lives and property, and are committed to providing you with the best possible fire protection solutions.

stored pressure type list

ABC Powder Type

Specifications 1 kg 2 kg 4 kg 6 kg 9 kg
Fire Rating - MAP 50
1A 21B
2A 34B
3A 55B
4A 144B
6A 144B
Fire Rating - MAP 90
1A 21B
2A 55B
3A 89B
4A 144B
6A 233B
Working Temperature C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
Min. Effective Discharge Time
8 sec
13 sec
13 sec
15 sec
15 sec
Propellant
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Charge
ABC Dry Powder (MAP50 / MAP90)
ABC Dry Powder (MAP50 / MAP90)
ABC Dry Powder (MAP50 / MAP90)
ABC Dry Powder (MAP50 / MAP90)
ABC Dry Powder (MAP50 / MAP90)

One of the most versatile type of firefighting equipment, dry powder fire extinguishers are the most popular choice because of their capability for protection against light, ordinary and high hazards. ABC dry chemical powder fire extinguishers are suitable for use on Class A (ordinary solids), Class B fires (flammable liquids) and Class C fires (flammable gases). The ABC type fire extinguishers can also be used on electrically actuated fires. Dry powder fire extinguishers carry a blue colour band which is clear and easy to see in the event of any emergency.

Dry powder stored pressure fire extinguishers filled with silicon coated mono ammonium phosphate dry chemical powder is available with MAP 50% or MAP 90% as per customer requirements.

With a choice of portable stored pressure type extinguishers, our range caters to all customer requirements.

BC Powder Type

minimaxfire
Specifications 1 kg 2 kg 4 kg 6 kg 9 kg
Fire Rating
34B
55B
89B
144B
233B
Working Temperature C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
Operating Pressure
15 bar
15 bar
15 bar
15 bar
15 bar
Min. Effective Discharge Time
8 sec
9 sec.
9 sec
15 sec
15 sec
Propellant
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Charge
Sodium Bi-Carbonate
Sodium Bi-Carbonate
Sodium Bi-Carbonate
Sodium Bi-Carbonate
Sodium Bi-Carbonate

BC Powder Type variant contains sodium bicarbonate powder for fighting against light and ordinary fire hazard. It is effective on Class B fires (flammable liquids) and Class C fires (flammable gases). Extinguishers uses cooling and blanketing effect to slow down fire and eventually extinguishing the fire. BC dry chemical powder is Free-flowing, water repellent, non-abrasive.

These types of extinguishers are mostly used in industries where ordinary Class B and Class C combustible material is stored in large quantity. Dry powder fire extinguishers carry a blue colour band which is clear and easy to see in the event of any emergency.

With a choice of portable stored pressure type extinguishers, our range caters to all customer requirements.

Water Type

Specifications 2 ltr 6 ltr 9 ltr
Fire Rating
1A
3A
3A
Working Temperature C
+5 C to +60 C
+5 C to +60 C
+5 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
Operating Pressure
12 bar
12 bar
12 bar
Min. Effective Discharge Time
8 sec.
8 sec.
13 sec.
Propellant
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Charge
Water with Additive
Water with Additive
Water with Additive

Water type fire extinguishers are most preferred to tackle Class A (ordinary solids) fires involving common combustible materials such as wood, plastics and paper. These fire extinguishers should never be used on electrically actuated fires. Because of their effectiveness against fires involving everyday combustible materials water type fire extinguishers are preferred in most residential and commercial buildings. Water type fire extinguishers works on cooling principle. When extinguisher is operated by spraying a jet of water onto the fire, it penetrates the blaze resulting in flames being extinguished.

With a choice of portable stored pressure type extinguishers, our range caters to all customer requirements.

Mechanical Foam (AFFF) Type

Specifications 9 ltr
Fire Rating
4A 233B
Working Temperature C
+5 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
Operating Pressure
12 bar
Min. Effective Discharge Time
15 sec
Propellant
Dry Nitrogen
Charge
Water with AFFF 6%

Mechanical foam (AFFF) fire extinguishers, also known as foam fire extinguishers. They can be used on both Class A (ordinary solids) and Class B (flammable liquids) fires containing materials such as wood, paper and other solid combustibles as well as flammable liquids including petrol and spirits.

These fire extinguishers are almost commonplace in petrol stations, courtyards and factories where there is a dual risk of solid materials and flammable liquid fires. AFFF fire extinguisher after operating on fire prone area produces a layer which helps in cooling as well as blanketing effect results in extinguishing fire. Another key property of the foam is its ability to seep its way into absorbent fuel sources which prevents reigniting risks. Mechanical foam fire extinguishers carry a yellow colour band which is clear and easy to see in the event of any emergency.

Mechanical Foam type extinguishers should never be used on electrical fires, flammable gases, cooking fats & oils.

With a choice of portable stored pressure type extinguishers, our range caters to all customer requirements.

Mechanical Foam AR-AFFF

Specifications 9 ltr
Fire Rating
4A 233B
Working Temperature C
+5 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
Operating Pressure
12 bar
Min. Effective Discharge Time
15 sec
Propellant
Dry Nitrogen
Charge
Water with AR-AFFF 6X6%

Mechanical foam (AR-AFFF) fire extinguishers are suitable on water soluble flammable liquids like alcohols, ketones, amines, esters, ethers, aldehydes etc. in pure form as well as in mixture with hydrocarbons. These extinguishers can be used on both Class A (ordinary solids) and Class B (flammable liquids) fires containing materials such as wood, paper and other solid combustibles as well as flammable liquids including petrol and spirits. Mechanical Foam type extinguishers should never be used on electrical fires, flammable gases, cooking fats & oils.

Operating principle is similar as other foam type extinguisher but in case of polar solvents foam is produced by mixing foam concentrate with water and applied through aerating nozzles on alcoholic fires, after which a thick foam film is formed on the surface of the fuel blocking external air, thereby extinguishing the fire.

These fire extinguishers find special use in Hotels, Manufacturing Industries, Beverage Industries, Petrol Pumps, Water soluble Solvent Storage Areas e.g. Isopropyl Alcohols, Warehouses, CNG/PNG/LPG storage Areas, Laboratories, Printing Shops, Paint Dipping Operations, Oil Change Facilities. Mechanical foam fire extinguishers carry a yellow colour band which is clear and easy to see in the event of any emergency.

Clean Agent Type

Specifications 1 kg 2 kg 4 kg 6 kg 9 kg
Fire Rating
-
1A 21B
2A 34B
2A 55B
-
Working Temperature C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
Operating Pressure
8 bar
8 bar
8 bar
8 bar
8 bar
Min. Effective Discharge Time
8 sec.
8 sec.
13 sec.
13 sec.
13 sec.
Propellant
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Charge
HFC-236fa / FE-36TM
HFC-236fa / FE-36TM
HFC-236fa / FE-36TM
HFC-236fa / FE-36TM
HFC-236fa / FE-36TM

Minimax GRENOZ™ clean agent fire extinguishers contain environment friendly UL approved FE-36™ or HFC-236fa gas as an extinguishing agent. Clean agent is a fire suppressant stored as liquid that discharges in the form of gas. Minimax GRENOZ™ is effective for use on Class A (ordinary solids), Class B fires (flammable liquids) and Class C fires (flammable gases). These fire extinguishers can also be used on electrically actuated fires. These extinguishers are environmentally safe, leaves no residue and intended for the protection of facilities where electrical panels or electronic equipment’s are installed.

Clean agent extinguishers act to extinguish a fire by smothering effect. As the extinguishing agent does not conduct electricity back to the user, they are most effective on electrical fires.

Wet Chemical (F-Class) Type

Specifications 1 ltr 2 ltr 4 ltr 6 ltr 9 ltr
Fire Rating
-
5F
-
25F
75F
Working Temperature C
+5 C to +60 C
+5 C to +60 C
+5 C to +60 C
+5 C to +60 C
+5 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
Operating Pressure
12 bar
12 bar
12 bar
12 bar
12 bar
Min. Effective Discharge Time
8 sec
8 sec
13 sec
13 sec
13 sec
Propellant
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Charge
Wet Chemical (Potassium Based)
Wet Chemical (Potassium Based)
Wet Chemical (Potassium Based)
Wet Chemical (Potassium Based)
Wet Chemical (Potassium Based)

Minimax Kitchen (F-Class) Type fire extinguishers are designed for use on Class F fires which involves cooking oils and fat. Wet chemical is the only type of extinguisher to be used on kitchen (F-Class) fires. These extinguishers work by instigating a chemical reaction with fats and oils. This reaction reduces the temperature and eliminates the heat, causing flames extinguishment. The reason that no other type of extinguisher should be used on Class F fires is because they have pressurized jets and the pressure can result in burning oils and fats to end up in other surfaces and areas, creating a larger and uncontrollable blaze.

Wet chemical fire extinguishers have a unique nozzle which allows for application from a safer and further distance. A layer of cooling foam is emitted and forms layer on top of the burning materials. These extinguishers are specifically designed to combat kitchen fires and act as supplement to existing automatic kitchen hood fire suppression systems.

Minimax kitchen fire extinguishers are supplied in steel cylinder bodies as they are used in kitchens where hygiene and aesthetics are concern.

Minimax kitchen fire extinguishers shall be installed in small pantries, commercial and industrial kitchens, restaurants and hotels where cooking oils are commonly used.

ABC Powder (Minimax+) Type

Specifications 1 kg 2 kg
Fire Rating - MAP 90
1A 34B
2A 55B
Working Temperature C
-30 C to +60 C
-30 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
35 bar for 30 sec.
Min. Effective Discharge Time
9 sec
13 sec
Propellant
Dry Nitrogen
Dry Nitrogen
Charge
ABC Dry Powder (MAP90)
ABC Dry Powder (MAP90)

Minimax+ fire extinguishers are sleek and compact design models in ABC portable stored pressure type. These extinguishers are designed to match the aesthetics of premises besides protecting them from fire hazard. ABC dry chemical powder is suitable for use on Class A (ordinary solids), Class B fires (flammable liquids) and Class C fires (flammable gases). These extinguishers can also be used on electrically actuated fires. Dry powder fire extinguishers carry a blue colour band which is clear and easy to see in the event of any emergency.

These fire extinguishers filled with silicon coated mono ammonium phosphate dry chemical powder is available with MAP 90% ABC powder with 1 & 2 Kg capacities.

ABC Powder (Stainless Steel) Type

Specifications 1 kg 2 kg 4 kg 6 kg 9 kg
Fire Rating - MAP 50
1A 21B
2A 34B
3A 55B
4A 144B
6A 144B
Fire Rating - MAP 90
1A 21B
2A 55B
3A 89B
4A 144B
6A 233B
Working Temperature C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec
35 bar for 30 sec
35 bar for 30 sec
35 bar for 30 sec
35 bar for 30 sec
Operating Pressure
15 bar
15 bar
15 bar
15 bar
15 bar
Min. Effective Discharge Time
8 sec
13 sec
13 sec
15 sec
15 sec
Propellant
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Charge
ABC Dry Powder (MAP50 / MAP90)
ABC Dry Powder (MAP50 / MAP90)
ABC Dry Powder (MAP50 / MAP90)
ABC Dry Powder (MAP50 / MAP90)
ABC Dry Powder (MAP50 / MAP90)

ABC Powder Stainless Steel type fire extinguishers are used in special places like coastal and high salinity environments. Stainless steel has no ferrite properties, so it is highly corrosion resistant. These fire extinguishers are suitable for use on Class A (ordinary solids), Class B fires (flammable liquids) and Class C fires (flammable gases). The ABC type fire extinguishers can also be used on electrically actuated fires. Dry powder fire extinguishers carry a blue colour band which is clear and easy to see in the event of any emergency.

Dry powder stored pressure fire extinguishers filled with silicon coated mono ammonium phosphate dry chemical powder is available with MAP 50% or MAP 90% as per customer requirements.

With a choice of stainless-steel type portable stored pressure type extinguishers, our range caters to all customer requirements.

Water (Stainless Steel) Type

Specifications 2 ltr 6 ltr 9 ltr
Fire Rating
1A
3A
3A
Working Temperature C
+5 C to +60 C
+5 C to +60 C
+5 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
35 bar for 30 sec.
35 bar for 30 sec.
Operating Pressure
12 bar
12 bar
12 bar
Min. Effective Discharge Time
8 sec.
8 sec.
13 sec.
Propellant
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Charge
Water with Additive
Water with Additive
Water with Additive

Water type fire extinguishers are most preferred to tackle Class A (ordinary solids) fires involving common combustible materials such as wood, plastics and paper. These fire extinguishers should never be used on electrically actuated fires. Because of their effectiveness against fires involving everyday combustible materials water type fire extinguishers are preferred in most residential and commercial buildings. Water type fire extinguishers works on cooling principle. When extinguisher is operated by spraying a jet of water onto the fire, it penetrates the blaze resulting in flames being extinguished.

Extinguisher is made of stainless-steel cylinder which has no ferrite properties and is highly corrosion resistant. So, these extinguishers find special use in coastal and high salinity environments.

With a choice of portable stored pressure type extinguishers, our range caters to all customer requirements.

Mechanical Foam (AFFF) Stainless Steel Type

Specifications 9 ltr
Fire Rating
4A 233B
Working Temperature C
+5 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec.
Operating Pressure
12 bar
Min. Effective Discharge Time
15 sec
Propellant
Dry Nitrogen
Charge
Water with AFFF 6%

Mechanical foam (AR-AFFF) fire extinguishers, also known as foam fire extinguishers. They can be used on both Class A (ordinary solids) and Class B (flammable liquids) fires containing materials such as wood, paper and other solid combustibles as well as flammable liquids including petrol and spirits.

Extinguisher is made of stainless-steel cylinder which has no ferrite properties and is highly corrosion-resistant. So, these extinguishers find special use in coastal and high salinity environments.

These fire extinguishers are almost commonplace in petrol stations, courtyards and factories where there is a dual risk of solid materials and flammable liquid fires. AFFF fire extinguisher after operating on fire prone area produces a layer which helps in cooling as well as blanketing effect results in extinguishing fire. Another key property of the foam is its ability to seep its way into absorbent fuel sources which prevents reigniting risks. Mechanical foam fire extinguishers carry a yellow colour band which is clear and easy to see in the event of any emergency.

Mechanical Foam type extinguishers should never be used on electrical fires, flammable gases, cooking fats & oils.

With a choice of portable stored pressure type extinguishers, our range caters to all customer requirements.

Clean Agent Stainless Steel Type

Specifications 1 kg 2 kg 4 kg 6 kg 9 kg
Fire Rating
-
1A 21B
2A 34B
2A 55B
-
Working Temperature C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
-30 C to +60 C
Burst Pressure
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
55/80 bar min., 110 bar (actual) approx
Cylinder Testing Pressure
35 bar for 30 sec
35 bar for 30 sec
35 bar for 30 sec
35 bar for 30 sec
35 bar for 30 sec
Operating Pressure
8 bar
8 bar
8 bar
8 bar
8 bar
Min. Effective Discharge Time
8 sec
8 sec
8 sec
13 sec
13 sec
Propellant
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Dry Nitrogen
Charge
HFC-236fa / FE-36
HFC-236fa / FE-36
HFC-236fa / FE-36
HFC-236fa / FE-36
HFC-236fa / FE-36

Minimax GRENOZ™ clean agent fire extinguishers contain environment friendly UL approved FE-36™ or HFC-236fa gas as an extinguishing agent. Clean agent is a fire suppressant stored as liquid that discharges in the form of gas. Minimax GRENOZ™ is effective for use on Class A (ordinary solids), Class B fires (flammable liquids) and Class C fires (flammable gases). These fire extinguishers can also be used on electrically actuated fires. These extinguishers are environmentally safe, leaves no residue and intended for the protection of facilities where electrical panels or electronic equipment’s are installed.

Extinguisher is made of stainless-steel cylinder which has no ferrite properties and is highly corrosion resistant. So, these extinguishers find special use in coastal and high salinity environments.

Clean agent extinguishers act to extinguish a fire by smothering effect. As the extinguishing agent does not conduct electricity back to the user, they are most effective on electrical fires.

Applications of these extinguishers include boats, electrical panel and server rooms, computer Rooms, clean rooms, switch rooms and telecoms, data storage areas and art storage rooms.